Specialised reinforced glass with triple diaphragm and double juction electrode highly sensitive real-time
response measurement for aggressive processes.
Characterised by consistent measurement results in aggressive environment
conditions maintaining reliable readings delivering excellent process control.
» Real-time measurement with short
response time provides efficient reliable process control long service life and consistent performance.
» Exceptional measurement precision with minimal interference caused by flow fluctuations with optimum performance
process control.
» Double juction redox electrode with tiple open hole diaphragm delivering an extra
barrier of protection against contamination.
Technical Features
| » Measurement :- ± 2000
mV | » Electrode :- Platinum Double Juction | » Triple Open Hole Diaphragm | » Electrolyte :- KCL
Gel |
| » Temp :- 130°C (6 Bar) | » Pressure :- 16 Bar (25°C) | » Body :- Reinforced Glass | » Conn :- PG13.5 | Dia
: - 12mm | » Length :- 120mm |
Applications
| Ammonia | Chrome Plating | Galvanic Processes | Reverse
Osmosis | Bisulfite Applications |
Glass body with sealed maintenance free electrolyte diaphragm and platinum electrode real-time measurement delivers
increased system effiency.
Characterised by consistent measurement unaffected by flow fluctuations to maintain
reliable readings delivering excellent process control.
» Real-time measurement with short response
time provides efficient reliable process control long service life and consistent performance.
» Exceptional measurement
precision with minimal interference caused by flow fluctuations with optimum performance process control.
» Double
juction redox electrode with open hole diaphragm offering an extra barrier of protection against contamination.
Technical
Features
| » Measurement :- ± 1000 mV | » Electrode :- Platinum | » Diaphragm :- Open
Hole Diaphragm | » Electrolyte :- KCL Gel |
| » Temp :- 80°C | » Pressure :- 6 Bar | » Body
:- Glass | » Connection :- PG13.5 | Diameter : - Ø 12mm | » Length :- 120mm
|
Applications
| Anti-Legionella Disinfection | Drinking Water | Galvanic Processes | Process
Water |
Robust polycarbonate body with sealed maintenance free electrolyte and platinum electrode real-time measurement delivers
increased system effiency.
Characterised by consistent measurement unaffected by flow fluctuations to maintain
reliable readings delivering excellent process control.
» Real-time measurement with short response
time provides efficient reliable process control long service life and consistent performance.
» Exceptional measurement
precision with minimal interference caused by flow fluctuations with optimum performance process control.
» Redox probes
available with single junction or double junction format offering an extra barrier of protection against contamination.
Technical
Features
| » Measurement :- ± 1000 mV | » Electrode :- Platinum junction | » Diaphragm :- Pellon
PTFE | » Electrolyte :- KCL Gel |
| » Temp :- 60°C | » Pressure :- 4 Bar | » Body
:- Epoxy | » Cable :- 6 Meters | Dia : - Ø 12mm | » Length :- 122mm |
Applications
| Cooling
Systems | Swimming Pools | Drinking Water | Irrigation Systems | Process Water | Laboratory|
Redox Electrodes
Applications
- Wastewater Treatment
-
- Water Treatment
-
- Swimming Pools
-
- Drinking Water
-
- Laboratory
-
- Irigation
Redox (ORP) Sensors
Redox probes and redox electrodes designed to deliver precise and reliable measurement delivering
increased process effiency and control wide choice of sensors with different material constructions and reference systems
available to achieve long service life, critical for processes that require continuous real-time stable readings particularly environments
where temperature-pressure or aggressive chemical agents are a consideration when choosing a suitable redox
electrode being an integral part of the process that isn't dependent on regular maintenance.
Redox Probes
Polycarbonate Body
Redox Electrodes
Glass Body
Redox Measurement Principal
Typically used to determine oxidizing or reducing potential of a water sample for
the tendency of a chemical species to acquire electrons from or lose electrons to an electrode thereby reduced or oxidised respectively, using
a platinum tip electrode with the value being presented millivolts (mV), the term Redox is derived from Reduction
Oxidation and also be referred to as ORP (Oxidation Reduction Potential).
Redox (ORP) Electrode
Reinforced Glass
Redox Controllers & Instruments
Electronic Dosing Systems
Tel 01299 825 656 Email info@electronicdosingsystems.co.uk
Copyright: - Electronic Dosing Systems 2024
| Water Treatment | Electroplating | Cooling Towers | Industrial Boilers | Beverage & Breweries | Vehicle
Washing | Waste Water Treatment | Swimming Pools & Spas |
| Paper Industry | Petroleum | Bottle Washing |
Hygiene & Cleaning | Biotechnology | Food Industry | Pharmaceutical Industry |
Robust epoxy body with sealed maintenance free electrolyte and platinum electrode real-time measurement delivers
increased system effiency.
Characterised by consistent measurement unaffected by flow fluctuations to maintain
reliable readings delivering excellent process control.
» Real-time measurement with short response
time provides efficient reliable process control long service life and consistent performance.
» Excellent measurement reliability
regardless of environment conditions delivering increased chemical effiency with minimal servicing.
» Redox probes
available in single junction or double junction format offering an extra barrier of protection against contamination.
Technical
Features
| » Measurement :- ± 1000 mV | » Electrode :- Gold junction | » Diaphragm :- Pellon
PTFE | » Electrolyte :- KCL Gel |
| » Temp :- 60°C | » Pressure :- 6 Bar | » Body
:- Epoxy | » Cable :- 6 Meters | Dia : - Ø 12mm | » Length :- 122mm |
Applications
| Laboratory | Swimming
Pools | Water Monitoring |
Redox Electrodes
Epoxy Body