Redox Controllers
Applications
- Wastewater Treatment
- Reverse Osmosis
- Cooling Towers
- Drinking Water
- Irrigation
- Boilers
- Dairy
Electronic Dosing Systems
Tel 01299 825 656 Email info@electronicdosingsystems.co.uk
Proportional Redox (ORP) Control
Pulse Frequency Modulation
Relays generates a volt free pulse signal that
is connected into a dosing pump adjusting flow output decreasing proportionally until the set-point
threshold has been achieved delivering greater precision increased chemical effiency and control, alternatively used
as an auxiliary signal to drive remote control equipment or integrated in complex process systems and applications.
Pulse Width
Modulation
Set-point relays are activated on a timed cycle proportional to the measured chlorine value in respect
to the desired set point threshold decreasing the relay activated time until the desired redox (orp) level
is achieved, being a cost efficient solution to proportional control in numerous process applications when operating equipment
such as solenoid valves intermittently through a 230v supply.
Redox Controllers
Exceptional measurement precision and acuracy with large graphic display intuitive
navigation menu and extensive features and functions to maintain redox levels within specific boundaries,
controllers can be used either as a stand alone system or integrated into more complex dosing systems
where remote visualization and full programming authority can be accessed.
Characteristics Common To All Controllers
» Auxiliary outputs for
equipment or sensor cleaning
» Programmable maximum dosing time
»
Auxilary programming of days and time operations » Temperature compensate sensor set point
» Timer
program to start-up and end unit operations
» Graphic charts and data logger download
» Real-time configurable timer to drive controller » Automatic measured parameter recognition
Redox Controller
Instrument characterised by isolated measurement graphic display with active outputs and alarm status
icons.
Parameters configured for process-specific tasks with real-time measurement for reliable process control.
»
Programmable Set-Points :- On/Off Activation - Timed Activation - Smart Proportional Modulation.
» Alarm Messages :- Probe Failure - Temperature
- Flow - Set-Point Time-Out.
» Redox probe effiency can be maintained utilising the washing cycle function.
» Stabilised 100÷240v
power supply delivers reduced energy consumption.
» Remote communication websever hub with full programming authority
Technical
Features
| 2 x Set-Points | 1 x 4÷20 mA Output | 1 x Flow Input | 2 x Temp Sensor |1 x Alarm Output 230v |
| Dimensions :- » Wall Mounting (144 x 144 x 122) » Panel Mount Version (96 x 96 x 42)
Measurement Options;
| pH| Chlorine | Redox | Conductivity | Bromine | Peracetic Acid |
| Hydrogen Peroxide | Dissolved Oxygen | Ozone | Temperatue|
MT200-RX Redox
(ORP) Controllers
Redox PID Controller
Instrument characterised by isolated measurement graphic display with active outputs
and alarm status icons.
Parameters configured for process-specific tasks with real-time measurement for reliable
process control.
» Simualtaneous smart intelligent display changes colour according to current working
conditions
» Programmable PID Outputs :- Programme set-point parameters according to a PID algorithm
» Alarm
Messages :- Probe Failure - Temperature - Flow - Set-Point Time-Out .
» Redox probe effiency
can be maintained utilising the washing cycle function .
» Remote communication websever hub with
full programming authority
Technical Features
| 2 x Set-Points | 1 x 4÷20 mA Output | 1 x Flow
Input | 2 x Temp Sensor | 1 x Alarm Output 230v |
| Dimensions :- » Wall Mounting (144 x 144
x 122) » Panel Mount Version (96 x 96 x 42)
» Stabilised 100÷240v power supply delivers
reduced energy consumption.
Measurement Options;
| pH | Chlorine | Redox | Conductivity | Bromine | Peracetic Acid |
| Hydrogen
Peroxide | Dissolved Oxygen | Ozone | Temperatue |
MT400-RX Redox
(ORP) Controllers
QR Codes
Controller Configurations
Advanced Settings
Redox Controllers
Instrument with isolated measurement and graphic display suitable for complex water-treatment applications.
Parameters
configured for process-specific measurement tasks from basic to advanced program schedules.
»
Self-explanatory intuitive navigation menu programming according to complexity of working parameters.
» Simpified
and professional program level menu's to adapt parameters to application specific control.
» Programmable
Set-Points Modes :- On/Off activation - Proportional width modulation (pwm) activation.
» Set-Points Parameters :-
Hysteresis - Delay Start - Max Dosage Time - Low-High Phreshold Alarm.
» Remote 485 serial port modbus communication websever
hub with full programming authority.
Technical Feature
| 2 x Set-Points | 1 x 4÷20 mA Outputs | 1 x
4÷20 mA Chart-Recorder | 1 x Level Input |
| 1 x Flow Switch Input | 1 x Temperature
Sensor (PT100) | 1 x Alarm Output 230v |
» Dimensions :- 231 x 125 x 90 Enclosure IP66 Protection
Measurement Options;
| pH| Chlorine | Redox | Conductivity | Bromine | Peracetic Acid |
| Hydrogen Peroxide | Dissolved Oxygen | Ozone | Temperatue|
DC100-RX Redox
(ORP) Controllers
Universal 100÷240v
Power Supply
Electrodes - Probes - Sensors
Copyright: - Electronic Dosing Systems 2024
| Water Treatment | Electroplating | Cooling Towers | Industrial Boilers | Beverage & Breweries | Vehicle
Washing | Waste Water Treatment | Swimming Pools & Spas |
| Paper Industry | Petroleum | Bottle Washing |
Hygiene & Cleaning | Biotechnology | Food Industry | Pharmaceutical Industry |