Redox Controllers
 
 
 
Applications
 

Redox instrument's with touch screen technology high level specifications and remote programming access Redox controllers for continuous monitoring and accuracy with precision for all types of application's Redox controllers - redox dosing systems precise measurement control and reliability with extensive program functions
Product Enquiry
Redox controllers - redox control systems programmable PID algorithm outputs for continuous reliable performance Redox controllers - redox systems excellent precision and control self explanatory navigation menu and probe efficiency  program
pH Electrodes
Redox Electrodes
Conductivity Probes
Conductivity Electrodes
Chlorine- Chlorine Dioxide Sensors
Bromine-Hydrogen Preoxide-Peracetic Acid Sensors
Electrodes-Probes Sensors
Home
Contact us
pH Controllers
Redox Controllers
Chlorine Controllers
Conductivity Controllers
Multifunction Controllers
Digital Instruments
Controllers
Dosing Pumps Constant Operation
Dosing Pumps Digital Microprocessor
Dosing Pump with pH, Redox Controllers
Dosing Pumps ATEX Zone 2
Dosing Pump Accessories
Solenoid Dosing Pumps
Chemical Dosing Tanks
Water Meters
Dosing Tanks
Water Meters
Inline Probe Holders
By-Pass Probe Holders
Submersible Probe Holders
Electrodes-Probes Holders
Electronic Dosing Systems
 
Tel 01299 825 656 Email info@electronicdosingsystems.co.uk
Mechanical Diaphragm Pumps
Motor-Driven Piston Metering Pumps
Motor-Driven Digital Metering Pumps
Metering Pump Accessories
Motor-Driven
 Metering Pumps

Proportional Redox (ORP) Control
 
Pulse Frequency Modulation 
Relays generates a volt free pulse signal that is connected into a dosing pump adjusting flow output decreasing proportionally until the set-point threshold has been achieved delivering greater precision increased chemical effiency and control, alternatively used as an auxiliary signal to drive remote control equipment or integrated in complex process systems and applications.
 
Pulse Width Modulation 
Set-point relays are activated on a timed cycle proportional to the measured chlorine value in respect to the desired set point threshold decreasing the relay activated time until the desired redox (orp) level is achieved, being a cost efficient solution to proportional control in numerous process applications when operating equipment such as solenoid valves intermittently through a 230v supply.

Redox Controllers
 
Exceptional measurement precision and acuracy with large graphic display intuitive navigation menu and extensive features and functions to maintain redox levels within specific boundaries, controllers can be used either as a stand alone system or integrated into more complex dosing systems where remote visualization and full programming authority can be accessed. 

Characteristics Common To All Controllers

            »  Auxiliary outputs for equipment or sensor cleaning                             »  Programmable maximum dosing time
            »  Auxilary programming of days and time operations                             » Temperature compensate sensor set point

            »  Timer program to start-up and end unit operations                                » Graphic charts and data logger download
            »  Real-time configurable timer to drive controller                                  »  Automatic measured parameter recognition

Redox Controller
 
Instrument characterised by isolated measurement graphic display with active outputs and alarm status icons.
Parameters configured for process-specific tasks with real-time measurement for reliable process control.
 
»  Programmable Set-Points :- On/Off Activation - Timed Activation - Smart Proportional Modulation.
»  Alarm Messages :- Probe Failure - Temperature - Flow - Set-Point Time-Out.
»  Redox probe effiency can be maintained utilising the washing cycle function.
 
»  Stabilised 100÷240v power supply delivers reduced energy consumption.
»  Remote communication websever hub with full programming authority
 
Technical Features
| 2 x Set-Points 1 x 4÷20 mA Output 1 x Flow Input 2 x Temp Sensor |1 x Alarm Output 230v |
| Dimensions :- » Wall Mounting (144 x 144 x 122) »  Panel Mount Version (96 x 96 x 42)
 
Measurement Options;
| pH| Chlorine | Redox | Conductivity | Bromine | Peracetic Acid |
| Hydrogen Peroxide | Dissolved Oxygen | Ozone | Temperatue|
 

MT200-RX Redox
(ORP) Controllers

Redox PID Controller
 
Instrument characterised by isolated measurement graphic display with active outputs and alarm status icons.
Parameters configured for process-specific tasks with real-time measurement for reliable process control.
 
»  Simualtaneous smart intelligent display changes colour according to current working conditions
»  Programmable PID Outputs :- Programme set-point parameters according to a PID algorithm
»  Alarm Messages :- Probe Failure - Temperature - Flow - Set-Point Time-Out .
»  Redox probe effiency can be maintained utilising the washing cycle function .
 
»  Remote communication websever hub with full programming authority
 
Technical Features
| 2 x Set-Points 1 x 4÷20 mA Output 1 x Flow Input 2 x Temp Sensor | 1 x Alarm Output 230v |
| Dimensions :- » Wall Mounting (144 x 144 x 122) »  Panel Mount Version (96 x 96 x 42)
»  Stabilised 100÷240v power supply delivers reduced energy consumption.
 
Measurement Options;
| pH | Chlorine | Redox | Conductivity | Bromine | Peracetic Acid |
| Hydrogen Peroxide | Dissolved Oxygen | Ozone | Temperatue |
 

MT400-RX Redox
(ORP) Controllers
Product Enquiry
QR Codes
Controller Configurations
Advanced Settings

Redox Controllers
 
Instrument with isolated measurement and graphic display suitable for complex water-treatment applications.
Parameters configured for process-specific measurement tasks from basic to advanced program schedules.
 
»  Self-explanatory intuitive navigation menu programming according to complexity of working parameters.
»  Simpified and professional program level menu's to adapt parameters to application specific control.
 
»  Programmable Set-Points Modes :- On/Off activation - Proportional width modulation (pwm) activation.
»  Set-Points Parameters :- Hysteresis - Delay Start - Max Dosage Time - Low-High Phreshold Alarm.
 
»  Remote 485 serial port modbus communication websever hub with full programming authority.
 
Technical Feature
| 2 x Set-Points 1 x 4÷20 mA Outputs 1 x 4÷20 mA Chart-Recorder 1 x Level Input | 
| 1 x Flow Switch Input | 1 x Temperature Sensor (PT100) | 1 x Alarm Output 230v |
»  Dimensions :- 231 x 125 x 90 Enclosure IP66 Protection
 
Measurement Options;
| pH| Chlorine | Redox | Conductivity | Bromine | Peracetic Acid |
| Hydrogen Peroxide | Dissolved Oxygen | Ozone | Temperatue|

DC100-RX Redox
(ORP) Controllers

Product Enquiry
Universal 100÷240v
Power Supply
Electrodes - Probes - Sensors
 
 
 