Electronic Dosing Systems Ltd
Ryelands Business Centre, Elmley Lovett, Droitwich, Worcestershire, WR9 0PT
 Email info@electronicdosingsystems.co.uk Tel 01299 825 656
Cloud Connectivity Upload
   Copyright: - Electronic Dosing Systems 2020
electronic_dosing_systems_ltd002005.jpg
S
Touch screen technology display with up to four parameters
Basic and advanced professional programming menus.

pH Instrument measurement 0÷14 pH ( acid | alkali ) reading range
 
Redox instrument measurement 0÷1999 mV millivolts reading range
 
Chlorine instrument measurement 0÷2 ppm | 0÷10 ppm | 0÷10 ppm |
 
Conductivity instrument measurement K=1 or K=5 constant probes
 
| PPM measurementsBromine Instrument | Chlorine Dioxide instrument |
| Hydrogen Peroxide instrument | Peracetic Acid instrument | Active oxygen |
 
Download Brochure
Send Enquiry
  Product Information

• Touch Screen Display With Graphic Icons-Outputs Status and Alarm Messages

• Real Time Clock Configurable To Drive Controller Functions Over Measurements

• Hysteresis - Set Point Start Delay - Over Dosing Time Alarm - Max/min Alarm

• Ethernet (LAN) connection; SmartApp® Software; Modbus TCP and USB Port

• Set Point Modes; On/Off and Proportional (PWM) Timed Modes; pH Priority

• Chemical Tank Level Probe Input Protection (Isolates Power To Pumps)

• Remote Communication For Programming Of Instrument Parameters

• Auxiliary Timer Outputs For Programming of Remote Equipment

• Graphic Charts and Data Logger Download

Measurement of pH controller
The measurement of Hydrogen Ion concentration in an aqueous liquid, which determines whether a liquid is neutral (7.0 pH), acid or alkali. pH is usually measured with a glass or plastic combination electrode which produces a millivolt potential proportional to the pH value that is amplified by the software inside the pH instrument to give an instantaneous value.
 
Measurement of Redox controller
Typically used to determine the oxidizing or reducing potential (ORP) of a water sample solution being a measure of the tendency of a chemical species to acquire electrons from or lose electrons to an electrode and thereby be reduced or oxidised respectively, using a platinum tip electrode with the the value being presented millivolts (mV), the term Redox is derived from Reduction Oxidation and also be referred to as ORP (Oxidation ReductionPotential).
 
Measurement of Chlorine controller
Used in many industrial applications as a disinfectant residual chlorine or free chlorine is the primary measurement for chlorine instrumentation, colorimeters typically detect chlorine in the range of 0 to 5 parts per million (ppm) a more sophisticated technique is based on the amperometric method with chlorine measured by a sensor probe containing the electrolyte potassium chloride (KCl).
 
Measurement of Conductivity controller
Conductivity is the measurement of electrical conductance of all dissolved ionic species within a measured solution by determining the resistance of the solution between the conductivity electrode surfaces, used routinely in many industrial and environmental applications as a fast and inexpensive reliable way of measuring the total dissolved solids (T.D.S) content in a solution.
 
All controllers incorporate control relays as well as a (0) 4-20mA signal. Depending on which model of controller - these can be used to control a piece of control equipment such as a pump or solenoid valve. Often these pieces of control equipment can be controlled proportionally that is - causing the device to speed up, or dose faster / slower depending on the deviation from the desired set-point.

Touch screen chlorine instrument,pH instrument, redox instrument, conductivity instrument, chlorine dioxide instrument Touch screen chlorine controller, pH controller, redox controller, conductivity controller, bromine controller

TS300 Instrument Controllers
| pH instrument | Redox instrument | Chlorine instrument |
| Conductivity instrument | Bromine instrument | Chlorine dioxide |

TS400 Instrument Controllers
| pH controller | Redox controller | Chlorine controller |
| Conductivity controller | Bromine controller | Chlorine dioxide |

Touch screen technology display with up to three parameters
Basic and advanced professional programming menus.

pH Instrument measurement 0÷14 pH ( acid | alkali ) reading range
 
Redox instrument measurement 0÷1999 mV millivolts reading range
 
Chlorine instrument measurement 0÷2 ppm | 0÷10 ppm | 0÷10 ppm |
 
Conductivity instrument measurement K=1 or K=5 constant probes
 
| PPM measurementsBromine Instrument | Chlorine Dioxide instrument |
| Hydrogen Peroxide instrument | Peracetic Acid instrument | Active oxygen |
 
| Chlorine Sensors | pH Electrodes | Redox Electrodes | Conductivity Probes | Dosing TanksPotable Tanks | Water Meters |Dosing Hose |
Chlorine Dioxide | Pool Systems | Peristaltic Pumps | Peristaltic Systems | Freestanding Systems |Panel Systems | Process Timers |
|Pump Spares | Pump Accessories | Legionella Control | Wall Mount Pumps | Tank Mount Pumps |Instrument Pumps |
| Water Treatment | Electroplating | Cooling Towers | Industrial Boilers | Beverage & Breweries | Vehicle Washing | Waste Water Treatment | Swimming Pools & Spas |  
| Paper Industry | Petroleum | Bottle Washing | Hygiene & Cleaning | Biotechnology | Food Industry | Pharmaceutical Industry | 
Contact Us
Wall Mounting Dosing Pumps
Tank Mounting Dosing Pumps
Instrument Dosing Pump
Motor Driven Pumps
Peristaltic Pumps
Injection Fittings
Footvalve Fittings
Pump Injection Lances
Dosing Pump Hose
Dosing Pumps
Touch Screen pH and Redox Instruments
Touch Screen Chlorine Instruments
Touch Screen Conductivity Instruments
pH and Redox Controllers
Chlorine Controllers
Conductivity Controllers
Cooling Tower Controllers
Instrumentation
Home
MX Pool Dosing Systems
Peristaltic Dosing Systems
Panel Dosing Systems
Chlorine Dioxide Systems
Process Timer Controllers
Dosing Systems
Dosing Tanks and Bunds
Fresstanding Dosing Systems
Water Meters
Dosing Pump Hose
Accessories
Electrodes pH and Redox
Conductivity Probes
Chlorine Sensors
Electrodes