Electronic Dosing Systems Ltd
Ryelands Business Centre, Elmley Lovett, Droitwich, Worcestershire, WR9 0PT
Email info@electronicdosingsystems.co.uk Tel 01299 825 656
S
Pump Specifications
• Outputs to 20L/Hr with 20% and 100% frequency adjustment
• Reliable and robust design including LED frequency
indication
• Keypad output selection provides two dosing output ranges
• Manual stroke length available for precise dosing
control
• Manual bleed with hose connection for chemical priming
• Optional low level with level probe connected to footfilter
• Supplied with
footfilter injection fitting installation kit
• Dosing head options Antigasing-PVC-PVDF-PTFE
Tank mounting dosing pumps for constant operation with frequency and stroke length adjustments covering a full spectrum of dosing outputs, the electronic components and mechanical parts provide a very robust designed pump with consistant performance and years of trouble free service.
Normally controlled using a instrument to power the pump they are designed to dose a precise volume of chemical into a pipeline or tank, occasionally when aggressive chemicals are being dosed alternative dosing heads and fitting are required for to ensure the integrity of the pumps performance.
FX metering Pump
Tank Mounting
FX Metering Pump
Tank Mounting
Pump Specifications
• Outputs up to 20L/Hr with digital display and program keys
• Manual stroke length available
for precise dosing control
• Proportional meter controlled and 0÷20mA analog models
• Multifunction pump with proportional and seven
day timer
• Manual bleed with hose connection for chemical priming
• Optional low level with level probe connected to footfilter
•
Supplied with footfilter injection fitting installation kit
• Dosing head options antigasing--PVC-PVDF-PTFE
Digital dosing pumps covering a full spectrum of dosing outputs in a polypropylene housing with stoke length adjustment to
give additional control, alternative heads and fittings are available for aggressive chemicals to ensure years of trouble
free service. Pumps can be programmed in proportional or 4÷20mA modes alternatively dosing using the internal
timer program, chemical low level and flow protection and service relay output signal.
Model MX C/A
Constant operation metering pump with analogue 0-100% manual adjustment including frequency
reduction mode for low flow rate requirements whilst maintaining accuracy performance across both
dosing output ranges, selection of pump output range is through the touchpad with LED indication confirming the pumps flow
output between 100% frequency range and 20% frequency range.
MX C/AL model with low level protection and LED alarm
(level switch on request).
Model P/D
Metering pump with digital display and programming keypad indication
LED's for power, water meter, low level protection with Divide and Multiply modes with pulse smart memory
software that monitors water meter signal frequency and automatically adjusts the pumps stroke speed to ensure
harmonious and stable dosing throughout.
low level protection and LED alarm (level switch on request).
Model Multifunction
Microprocessor metering pump with
digital display with programming keypad indication LED's for power, input signal and low level protection
with Manual, Divide Multiply and PPM proportional modes, proportional 4÷20mA input signal normally from a instrument
controller or flow sensor signal, internal 7 day timer to program for the pump to run for a preset time either hourly, daily
or weekly to automatically dose into the system.
PPM Dosing
Proportional parts per million dosing using a impulse water
meter to is commonly used in many water treatment applications particularly dosing chlorine or sodium hypochlorite to maintain
ppm levels in the system, by programming the pulse signal, chemical concentration, cc/injection and the required
PPM the pump will automatically dose calculating flow to the required ppm maintaining the desired chemical treatment.
Proportional
4÷20mA
Pump is controlled by a 4÷20mA signal to adjust the stroke rate proportional to the incoming mA signal
therefore a 4mA signal dosing is stopped pump in standby as the value increases the pumps
strokes frequency until the input signal reaches 20mA with the pump dosing at maximum output. The pumps behaviour
can be reversed with 4mA 100% dosing and 20mA dosing in standby with stroke rate programming of minimum and
maximum pump output, increasing milliamp signal when pump is stopped and descreasing milliamp signal to have pump dosing
at maximum output.
Manual Mode
Metering pump can be programmed to operate within its stroke frequency rate with the
output controlled in three ways as a simple yet effective way of providing chemical dosing on a continuous cycle throughout the
day, the pump pulse frequency can be set pulses per minute, pulses per hour pulses per day.
Timed Dosing Mode
By using
the metering pumps internal timer dosing can be scheduled either daily or weekly providing independent and effective
way of chemical treatment without dependance of any external equipment, the pump can be programmed to dose eight times daily or
dose eight times per week.
Alarm features
Audible buzzer can be enabled for missed pump pulses
Water meter pulse frequency
prgram exceeded
Flow sensor when enabled will monitor dosing output of the pump and activate the service relay output alarm in
the event there is no signal being received from the flow sensor indicating chemical isn't' being dosed.
Copyright: - Electronic Dosing Systems 2020
| Water Treatment | Electroplating | Cooling Towers | Industrial Boilers | Beverage & Breweries | Vehicle
Washing | Waste Water Treatment | Swimming Pools & Spas |
| Paper Industry | Petroleum | Bottle Washing |
Hygiene & Cleaning | Biotechnology | Food Industry | Pharmaceutical Industry |