Pump Specifications
• Small output pumps with 20% or 100% frequency adjustment
• Reliable and robust design including LED frequency
indication
• Keypad output selection provides two dosing output ranges
• Manual bleed with hose connection for chemical priming
•
Optional low level with level probe connected to footfilter
• Supplied with mounting bracket and installation kit
• Dosing head options
Antigasing-PVC-PVDF-PTFE
Pump Specifications
• Small output pumps with digital display and program keys
• Proportional meter controlled and 4÷20mA analog
models
• Multifunction pump with proportional and seven day timer
• Manual bleed with hose connection for chemical priming
• Optional
low level with level probe connected to footfilter
• Supplied with mounting bracket and installation kit
• Dosing head options antigasing--PVC-PVDF-PTFE
Electronic Dosing Systems Ltd
Ryelands Business Centre, Elmley Lovett, Droitwich, Worcestershire, WR9 0PT
Email info@electronicdosingsystems.co.uk Tel 01299 825 656
S
MX Dosing Pump
Wall Mounting
MX Dosing Pump
Digital Series
Copyright: - Electronic Dosing Systems 2020
Wall mounting dosing pump for constant operation for low dosing applications, electronic components and mechanical parts provide a robust designed pump with consistant performance and years of trouble free service. Normally controlled through a instrument these pumps are designed to dose a precise volume of chemical into a pipeline or tank, when aggressive chemicals are being dosed alternative dosing heads and fitting are required for to ensure the integrity of the pumps performance.
Microprocessor based dosing pump in a chemical resistant housing for wall & enclosure mounting applications, multifunction program
for various applications and control includes 4÷20mA, proportional water meter and internal seven day timed dosing program. With
alarms for chemical low level, flow protection audible alarm plus service relay output. For aggressive chemicals
alternative heads and fittings are available ensure years of trouble free service.
| Water Treatment | Electroplating | Cooling Towers | Industrial Boilers | Beverage & Breweries | Vehicle
Washing | Waste Water Treatment | Swimming Pools & Spas |
| Paper Industry | Petroleum | Bottle Washing |
Hygiene & Cleaning | Biotechnology | Food Industry | Pharmaceutical Industry |
Model MX C/A
Constant operation dosing pump with analogue 0-100% manual adjustment including frequency
reduction mode for low flow rate requirements whilst maintaining accuracy performance across both
dosing output ranges, selection of pump output range is through the touchpad with LED indication confirming the pumps flow
output between 100% frequency range and 20% frequency range.
MX C/AL model with low level protection and LED alarm
(level switch on request).
Model P/D
Dosing pump with digital display and programming keypad indication
LED's for power, water meter, low level protection with Divide and Multiply modes with pulse smart memory
software that monitors water meter signal frequency and automatically adjusts the pumps stroke speed to ensure
harmonious and stable dosing throughout.
low level protection and LED alarm (level switch on request).
Model Multifunction
Microprocessor dosing pump with
digital display with programming keypad indication LED's for power, input signal and low level protection
with Manual, Divide Multiply and PPM proportional modes, proportional 4÷20mA input signal normally from a instrument
controller or flow sensor signal, internal 7 day timer to program for the pump to run for a preset time either hourly, daily
or weekly to automatically dose into the system.
PPM Dosing
Proportional parts per million dosing using a impulse water
meter to is commonly used in many water treatment applications particularly dosing chlorine or sodium hypochlorite to maintain
ppm levels in the system, by programming the pulse signal, chemical concentration, cc/injection and the required
PPM the pump will automatically dose calculating flow to the required ppm maintaining the desired chemical treatment.
Proportional
4÷20mA
Pump is controlled by a 4÷20mA signal to adjust the stroke rate proportional to the incoming mA signal
therefore a 4mA signal dosing is stopped pump in standby as the value increases the pumps
strokes frequency until the input signal reaches 20mA with the pump dosing at maximum output. The pumps behaviour
can be reversed with 4mA 100% dosing and 20mA dosing in standby with stroke rate programming of minimum and
maximum pump output, increasing milliamp signal when pump is stopped and descreasing milliamp signal to have pump dosing
at maximum output.
Manual Mode
Dosing pump can be programmed to operate within its stroke frequency rate with the output controlled
in three ways as a simple yet effective way of providing chemical dosing on a continuous cycle throughout the day, the pump pulse
frequency can be set pulses per minute, pulses per hour pulses per day.
Timed Dosing Mode
By using the dosing pumps internal timer dosing
can be scheduled either daily or weekly providing independent and effective way of chemical treatment
without dependance of any external equipment, the pump can be programmed to dose eight times daily or dose eight
times per week.
Alarm features
Audible buzzer can be enabled for missed pump pulses
Water meter pulse frequency prgram exceeded
Flow
sensor when enabled will monitor dosing output of the pump and activate the service relay output alarm in the event
there is no signal being received from the flow sensor indicating chemical isn't' being dosed.